ACU-150 & ACU-400 product recall
Find out moreThe RNS-5 network switch is designed for expanding Raymarine integrated chartplotter systems using RayNet high-speed Ethernet cabling. Use the RNS-5 to integrate Axiom displays with radars, sonar modules, IP cameras, and Teledyne FLIR thermal cameras. The RNS-5 also supports networking with Raymarine YachtSense digital control systems and the YachtSense Link marine mobile router. Two RNS-5 switches can be daisy-chained together for larger systems. The RNS-5 is simple to install and requires no complicated setup.
Environmental | |
---|---|
Relative Humidity | up to 93% @ 40 °C (104 °F) |
Waterproof rating | IPx6, IPx7 |
Non-operating temperature | -30 °C (-22 °F) to +70 °C (158 °F) |
Storage temperature | -25 °C to +70 °C (-13 °F to 158 °F) |
Operating temperature | -25 °C to +55 °C (-13 °F to 131 °F) |
Conformance | |
---|---|
Product markings | UKCA, CE, Australian Tick, WEEE Directive |
Standards | EN 60945:2002 (Europe, Australia New Zealand), EN ISO 8846:2017, ICES-003 (Canada), CFR47 Part 15 (USA), IACS section E10 (Japan / China), EMC Directive 2014/30/EU |
Physical | |
---|---|
Dimensions | Length: 286 mm (11.26 in), Width: 72.6 mm (2.86 in), Height: 55.5 mm (2.19 in) |
Port separation distance | 16.7 mm (0.65 in) |
Weight | 0.36 kg (0.79 lbs) |
Network | |
---|---|
IEEE Standard | Conforms to IEEE 802.3at |
Network connection ports | 5x waterproof RayNet connection ports (10/100/1000 Mbits/s) |
Ethernet speed | 10 / 100 / 1000 M/bits (Port 5 only) |
Power | |
---|---|
Nominal supply voltage | 12 V / 24 V dc |
Operating voltage range | 10.8 V to 31.2 V dc |
Power consumption | 3 W (Maximum) @ 12 V |
Thermal breaker rating | 3 A |
Inline fuse rating | 2 A |
Current | < 600 mA (nominal) @ 12 V |
1 | RNS-5 Network Switch |
2 | Documentation |
3 | Fixing screws (M4, 8.94 x 25 mm) |
4 | Power cable (1.5 m (4.9 ft)) |